Technical Parameters
Technical Parameters
Basic Parameters
ICR-1602 and ICR-1642
| Parameter | Condition | Value |
|---|---|---|
| Temperature Range | Operating Storage | -40 °C to +75 °C (-40 °F to +167 °F) -40 °C to +85 °C (-40 °F to +185 °F) |
| Humidity | Operating Storage | 5 to 95 % relative humidity, non-condensing 5 to 95 % relative humidity, non-condensing |
| Altitude | Operating | 2000 m / 70 kPa |
| Degree of Protection | IP30 | |
| Supply Voltage | 9 to 48 V DC | |
| Consumption (non-Wi-Fi / Wi-Fi) | Idle Average Maximum | 2.8 W / 3.8 W 3.5 W / 4.5 W 3.8 W / 5.5 W |
| Dimensions (without clips) | 94 × 39 × 90 mm (3.7" × 1.53" × 3.54") | |
| DIN Rail Clip (optional) | DIN 30 mm | |
| Weight | ICR-16XX: 331 g (0.73 lbs) (excluding accessories) LTE antenna: 25.2 g (0.06 lbs) Wall-mount bracket: 45 g (0.10 lbs) | |
ICR-1645
| Parameter | Condition | Value |
|---|---|---|
| Temperature Range | Operating Storage | -30 °C to +75 °C (-22 °F to +167 °F) -40 °C to +85 °C (-40 °F to +185 °F) |
| Humidity | Operating Storage | 5 to 95 % relative humidity, non-condensing 5 to 95 % relative humidity, non-condensing |
| Altitude | Operating | 2000 m / 70 kPa |
| Degree of Protection | IP30 | |
| Supply Voltage | 9 to 48 V DC | |
| Consumption (non-Wi-Fi / Wi-Fi) | Idle Average Maximum | 2.7 W / 3.6 W 3.7 W / 4.8 W 5.5 W / 6.8 W |
| Dimensions (without clips) | 116 × 39 × 113.5 mm (4.56" × 1.53" × 4.47") | |
| DIN Rail Clip (optional) | DIN 30 mm | |
| Weight | ICR-16XX: 470 g (1.04 lbs) (excluding accessories) LTE antenna: 25.2 g (0.06 lbs) Wall-mount bracket: 50 g (0.11 lbs) Wi-Fi antenna: 7.8 g (0.02 lbs) | |
Standards and Regulations
The routers comply with the following standards and regulations:
| Parameter | Description |
|---|---|
| Radio | EN 301 908-1, EN 301 908-2, EN 301 908-13, EN 301 908-25, EN 303 413, EN 300 328, EN 301 893 |
| EMC | EN 301 489-1, EN 301 489-17, EN 301 489-19, EN 301 489-52, EN 61000-6-2, EN 61000-6-3, EN 55032, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 |
| Safety | EN 62368-1 |
| Mechanical | EN 60529, EN 60068-2-27, EN 60068-2-64 |
| Climatic | EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-78 |
| National | ICR-16xx-EU: CE, UKCA compliant |
| Environmental | REACH, RoHS3 and WEEE compliant |
Type Tests and Environmental Specifications
Routers undergo the following tests to ensure durability and reliability:
ICR-1602 and ICR-1642
| Phenomena | Test | Description | Test levels |
|---|---|---|---|
| ESD | EN 61000-4-2 | Enclosure contact | ± 8 kV (crit. B) |
| RF field AM modulated | EN 61000-4-3 | Enclosure | 3 V/m (crit. A) (80 – 1000 MHz) |
| Fast transient | EN 61000-4-4 | Signal ports Power ports Ethernet ports | ± 0.5 kV (crit. A) |
| Surge | EN 61000-4-5 | Ethernet ports Power ports | ± 0.5 kV (crit. B) ± 1 kV (crit. B) open circuit |
| RF conducted | EN 61000-4-6 | All ports | 3 V/m (crit. A) (0.15 – 80 MHz) |
| Radiated emission | EN 55032 | Enclosure | Class B |
| Conducted emission | EN 55032 | Signal ports Power ports Ethernet ports | Class B Class B Class B |
| Dry heat | EN 60068-2-2 | Storage +85 °C (+185 °F) Operation +75 °C (+167 °F) | |
| Cold | EN 60068-2-1 | Storage -40 °C (-40 °F) Operation -40 °C (-40 °F) | |
| Damp heat | EN 60068-2-78 | 95 % rel. humidity (+40 °C / +104 °F) | |
| Dry heat, cyclic | EN 60068-2-30 | +55 °C (+131 °F) / +25 °C (+77 °F), 95 % rel. humidity, 12 h – 12 h | |
| Thermal shock / temp. variation | EN 60068-2-14 | -40 °C (-40 °F) / +75 °C (+167 °F), 3 h/3 h, 2 cycles, 3 K/min | |
| Degrees of protection | EN 60529 | IP30 | |
| Vibration | EN 60068-2-64 | Spectrum A.3 cat 1, breakpoints A.6 cat 1 | |
| Shock | EN 60068-2-27 | 50 m/s², 11 ms, half sine, 10 in each direction |
ICR-1645
| Phenomena | Test | Description | Test levels |
|---|---|---|---|
| ESD | EN 61000-4-2 | Enclosure contact | ± 8 kV (crit. B) |
| RF field AM modulated | EN 61000-4-3 | Enclosure | 3 V/m (crit. A) (80 – 1000 MHz) |
| Fast transient | EN 61000-4-4 | Signal ports Power ports Ethernet ports | ± 0.5 kV (crit. A) |
| Surge | EN 61000-4-5 | Ethernet ports Power ports | ± 0.5 kV (crit. B) ± 1 kV (crit. B) open circuit |
| RF conducted | EN 61000-4-6 | All ports | 3 V/m (crit. A) (0.15 – 80 MHz) |
| Radiated emission | EN 55032 | Enclosure | Class B |
| Conducted emission | EN 55032 | Signal ports Power ports Ethernet ports | Class B Class B Class B |
| Dry heat | EN 60068-2-2 | Storage +85 °C (+185 °F) Operation +75 °C (+167 °F) | |
| Cold | EN 60068-2-1 | Storage -40 °C (-40 °F) Operation -40 °C (-40 °F) | |
| Damp heat | EN 60068-2-78 | 95 % rel. humidity (+40 °C / +104 °F) | |
| Dry heat, cyclic | EN 60068-2-30 | +55 °C (+131 °F) / +25 °C (+77 °F), 95 % rel. humidity, 12 h – 12 h | |
| Thermal shock / temp. variation | EN 60068-2-14 | -30 °C (-22 °F) / +75 °C (+167 °F), 3 h/3 h, 2 cycles, 3 K/min | |
| Degrees of protection | EN 60529 | IP30 | |
| Vibration | EN 60068-2-64 | Spectrum A.3 cat 1, breakpoints A.6 cat 1 | |
| Shock | EN 60068-2-27 | 50 m/s², 11 ms, half sine, 10 in each direction |
Cellular Module Parameters
ICR-16xx-EU Variant
| Parameter | Description |
|---|---|
| Antenna | Connector type: SMA Input impedance: 50 Ω |
| LTE parameters | LTE: Cat.4, 3GPP Rel. 11 FDD bands: B1 (2100 MHz), B3 (1800 MHz), B7 (2600 MHz), B8 (900 MHz), B20 (800 MHz), B28A (700 MHz) TDD bands: B38 (2600 MHz), B40 (2300 MHz), B41 (2500 MHz) Bit rates: 150 Mbps (DL) / 50 Mbps (UL) |
| HSPA+/UMTS parameters | Supported frequencies: B8 (900 MHz), B1 (2100 MHz) Bit rates: 42 Mbps (DL) / 5.76 Mbps (UL) |
| EDGE/GPRS parameters | Supported frequencies: B8 (900 MHz), B3 (1800 MHz) Bit rates: 296 kbps (DL) / 236.8 kbps (UL) |
ICR-16xx-CN Variant
| Parameter | Description |
|---|---|
| Antenna | Connector type: SMA Input impedance: 50 Ω |
| LTE parameters | LTE: Cat.4, 3GPP Rel. 11 FDD bands: B1 (2100 MHz), B3 (1800 MHz), B5 (850 MHz), B8 (900 MHz) TDD bands: B34 (2000 MHz), B38 (2600 MHz), B39 (1900 MHz), B40 (2300 MHz), B41 (2500 MHz) LTE FDD bit rates: 150 Mbps (DL) / 50 Mbps (UL) LTE TDD bit rates: 130 Mbps (DL) / 30 Mbps (UL) |
| HSPA+/UMTS parameters | WCDMA bands: B1, B8 WCDMA bit rates: 384 kbps (DL/UL) TD-SCDMA bands: B34, B39 TD-SCDMA bit rates: 2.4 Mbps (DL) / 2.2 Mbps (UL) |
| EVDO/CDMA parameters | CDMA: 800 MHz EVDO bit rates: 3.1 Mbps (DL) / 1.8 Mbps (UL) |
| EDGE/GPRS parameters | Supported frequencies: EGSM 900 MHz, DCS 1800 MHz GPRS bit rates: 107 kbps (DL) / 85.6 kbps (UL) EDGE bit rates: 296 kbps (DL) / 236.8 kbps (UL) |
GNSS Parameters
Tips
This section applies to ICR-16xxG models only.
| Parameter | Description |
|---|---|
| GNSS Systems | GPS, Galileo, QZSS, GLONASS, BeiDou |
| Antenna | Connector type: SMA Input impedance: 50 Ω Supports active or passive antenna |
| Protocol | NMEA 0183 |
| Frequency | GPS: 1575.42 ± 1.023 MHz Galileo: 1575.42 ± 2.046 MHz QZSS: 1575.42 MHz GLONASS: 1597.5 – 1605.8 MHz BeiDou: 1561.098 ± 2.046 MHz |
| Sensitivity (autonomous) | Acquisition: −146 dBm Reacquisition: −157 dBm Tracking: −157 dBm |
| Acquisition Time (autonomous) | Cold start: 35.0 s Warm start: 26.0 s Hot start: 2.5 s |
| Accuracy | 2.5 m |
Wi-Fi Parameters
Caution
The 5 GHz Wi-Fi interface operates in frequency bands (specifically 5150–5350 MHz) that are restricted to indoor use only in certain EU member states. Refer to the regulatory documentation for your router model for details.
Tips
This section applies to ICR-16xxW models only.
| Parameter | Description |
|---|---|
| Antenna Connector | R-SMA — 50 Ω |
| Supported Wi-Fi Bands | 2.400 – 2.4835 GHz 5.150 – 5.850 GHz |
| Standards | IEEE: 802.11b, 802.11b/g, 802.11b/g/n, 802.11a, 802.11a+n, 802.11ac |
| 2.4 GHz Supported Channels | 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 |
| 5 GHz Supported Channels | 36, 40, 44, 48, 149, 153, 157, 161, 165 |
| Type of Device | Access point (AP), Station (STA) |
| Security — Standards | WPA, WPA2, WPA3, 802.1X |
| Security — Encryption | WEP, TKIP, AES |
| AP Maximum Users | Up to 16 clients |
I/O Parameters
Tips
This section applies to ICR-1642 and ICR-1645. ICR-1602 does not include I/O or serial interfaces.
The digital input status is available in the router's web interface (General Status page) and via the status ports and io get commands — refer to the Command Line Interface application note.
Characteristics of digital input:
io get output¹ | Status² |
|---|---|
| 1 | Open |
| 0 | Short to ISO_GND |
¹ The digital status returned by the io get shell command.
² The digital status returned by the status ports shell command and displayed on the General Status page.
The maximum digital output load is 500 mA at 48 V.
Serial Interfaces
Tips
The RS232 and RS485 interfaces can be configured in Expansion Port 1 and Expansion Port 2.
| Parameter | Description |
|---|---|
| Baudrate | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
| Data Bits | 5, 6, 7, 8 |
| Parity | None, even, odd |
| Stop Bits | 1, 2 |
| Flow Control | None, CTS/RTS |
System Configuration
| Parameter | Description |
|---|---|
| CPU Architecture | ARM Cortex-A7 |
| CPU Frequency | 1.2 GHz |
| CPU Power | 1.9 DMIPS/MHz |
| Flash Memory | 512 MB NAND: • ~65 MB for Router Apps • ~26 MB for customer data |
| RAM | Total: 256 MB; available: ~160 MB |
| Watchdog | HW watchdog |